LAMINAR AIR FLOW CABINET (HOOD) with vertical air down flow (product protection) for microelectronics
BAVnp-01-”Laminar-S” - 1,2 - ME (code 450.120) BAVnp-01-”Laminar-S” - 1,2 - ME (code 250.120)
Application
Assembly lines in instrument engineering and microelectronics; PCB and high-efficiency semiconductor indicator production, for high-class clean working zones in clean room
of low-class cleanliness. Laminar air flow cabinets provide local clean working zone inside clean laboratories.
There are two types of these cabinets:
- BAVnp-01-"Laminar-S"-1,2-ME (code 450.120)
- BAVnp-01-"Laminar-S"-1,2-ME (code 250.120)
- Moving tool storage drawer
- Corrosion-proof table surface made of unique dielectric plastic
- Additional sockets for different voltages (5V, 36V, etc.)
Laminar air flow cabinet provides sterile air environment protecting product from contaminated environment.
It has a front glass cut for microscope and is used for assembly work
Laminar air flow cabinet provides sterile air environment in the working zone and protects an operator from toxic,
volatile andsmelly substances and liquids, completely removing them from the working zone. The cabinet requires external air exhaust system
Distinctive features of BAVnp-01-"Laminar-S"-1,2-ME (code 250.120)
- Complete air exhaust from working zone to the external forced air ventilation
- Flat removable table surface made of special plastics
| Model BAVnp-01-«Laminar-S»-ME |
450.120 |
250.120 |
| External overall dimensions, mm (w/d/h) |
1170х695х1210 |
1170х740х1305 |
| Working chamber dimensions,mm (w/d/h) |
1105х620х670 |
1105х610х670 |
| Recirculation air volume, m3/h |
710 |
550 |
| Air flow velocity in the working chamberat a distance
of 150 mm from filter, m/sec |
0,45 ± 20% |
0,35 ± 20% |
| Power consumption,W |
600 |
600 |
| Weight, kg |
145 |
160 |
|
|
|